Our blog
& recent news

Laboratory Chillers Added to Organomation.com

Berlin, MA, July 10, 2015 – For years, Organomation has been an authorized distributor of PolyScience laboratory chillers. Organomation has expanded the Products section of the company’s website to..

Upgraded Needles Now Come Standard With N-EVAP Nitrogen Evaporators

January 05, 2015 /

News, Product Information

/ Organomation

Berlin, MA, January 5, 2015 – Organomation is proud to announce that instrument models in the company’s flagship product line, N-EVAP nitrogen evaporators, now come standard with fully stainless..

Determining Optimal Gas Flow in an N-EVAP Nitrogen Evaporator

December 05, 2014 /

Product Information

/ David Oliva

As stated earlier, at a given temperature the optimal gas flow may be defined as the highest velocity at which the gas jet can impinge on the solvent surface without causing excessive turbulence...

Factors Impacting Gas Flow in an N-EVAP Nitrogen Evaporator

November 11, 2014 /

Product Information

/ David Oliva

In previous discussions, it was noted that the two key factors affecting the evaporation rate of a given solvent are temperature and gas flow. Further, the evaporation rate of the subject solvent..

Organomation Announces Trade In Program for Laboratory Evaporators

August 01, 2014 /

News, Product Information

/ David Oliva

Berlin, MA, August 1, 2014 – Last month, Organomation announced a new program which allows customers to trade in their used evaporator or extractor for credit which will be applied towards a new..

Organomation Doubles the Warranty Length for Popular Evaporator Models

July 11, 2014 /

News, Product Information

/ David Oliva

Berlin, MA, July 11, 2014 – Earlier this year, Organomation proudly lengthened the standard warranty for some of its most popular nitrogen evaporators from one to two years. Since 1959, laboratory..

Organomation Upgrades Sample Holder in Popular Lab Evaporator

June 10, 2014 /

News, Product Information

/ David Oliva

Berlin, MA, June 10, 2014 – Organomation is happy to announce that the sample holders used in the company's popular N-EVAP product line have been upgraded. The company stands behind the quality of..

Refurbished Lab Equipment Sale Announced by Organomation

January 28, 2014 /

News, Product Information

/ Organomation

Organomation announces a sale on a wide variety of newly refurbished laboratory evaporators and extractors in the company's official online store. The evaporator manufacturer fully stands behind..

Optimum Temperature in a Nitrogen Evaporation Instrument

January 14, 2014 /

Product Information

/ Organomation

In a nitrogen evaporation instrument, temperature and gas flow rate are the two major operational parameters that determine the rate at which the solvent is removed from a system. However, it is..

Preventing Sample Contamination in an Evaporation System

December 30, 2013 /

Product Information

/ Organomation

It is often said that the best place to catch a disease is in a hospital; likewise, the most common place for sample contamination to occur is in the analytical laboratory. Sample contamination may..